Owner's Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
495
CobraNet Input and Output
The DME8i-C/DME8o-C/DME4io-C configuration window includes [CobraNet Input] and [CobraNet
Output] blocks.
CobraNet
Either double-click the block, or select [Open Input Component Editor] or [Open Output Component
Editor] from the context menu that appears when the block is right-clicked to open the component
editor. The displayed parameters are the same as for Slot In and Slot Out component editors.
Right-click the block and select [Open CobraNet Editor] from the contextual menu to open the editor.
* Select “Disable” if you intend to make settings via the CobraNet network using the CobraNet Manager, for example. In such
cases selecting “Enable” may result in incorrect settings.
Section Name/Parameter Range Function
1
Setting from this Editor Disable/Enable When “Disable” is selected settings made via the
CobraNet network take priority. When “Enable” is
selected settings made from the DME Designer
take priority.*
2
High
Sampling
Mode
Input Format DOUBLE
CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz sampling rates.
Linked to Output Format.
Output Format DOUBLE
CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz sampling rates.
Linked to Input Format.
3
Bundle
Number
Input 0 ~ 65279 Specifies the input bundle number.
Output 0 ~ 65279 Specifies the output bundle number.
4
Serial
Channel
Rx OFF, 1 ~ 15 Specifies the serial receive channel.
Tx OFF, 1 ~ 15 Specifies the serial transmit channel.
5
Properties Bit Length Bit Off
16bit
20bit
24bit
Specifies the output bit rate.
Output is muted when “Bit Off” is selected.
6
Latency 5.33ms
2.67ms
1.33ms
Specifies the latency.
7
Advanced - Opens the “Advanced Settings” window.
1
2
3
4
5
6
7
CobraNet Input/Output Component Editor