Owner`s manual

Basic Setup
DME Setup Manual 12
6 Checking sound output
In the case of DME24N, DME8i-C, DME4io-C, DME-
8i-ES or DME4io-ES units, appropriate HA control
settings must be made prior to checking the
system’s sound output.
6-1 Right-click the [Analog Input]
component and select [Open HA
Editor] from the drop-down menu.
An “Analog” dialog box that allows head amp
settings will appear.
By default, the gain is set to +10 dBu (i.e.,
the lowest possible gain).
6-2 Adjust the sensitivity to the correct
level for the connected audio
equipment.
n The level displayed by [Gain] is the sensitivity level to be
matched. As the sensitivity of most professional audio
equipment (using XLR connectors) is +4 dBu, the level
shown by [Gain] should be set to “4” in such a case.
When using input from microphones or other similar
sources, turn the dial clockwise to adjust the input volume
to a suitable level. Specifically, it is recommended that
the level shown by the input meter be peaking at around
-18 dB.