User Manual

Re
g
istration to obtain level meter c
y
cle
DME
SMC 0 500
(
settin
g
the c
y
cle for obtainin
g
the meter to 500 msec
)
SMC OK
GCMT 0 1 0
(
c
y
clicall
y
obtainin
g
ever
y
meter re
g
istered in "1"
)
GCMT OK
MTR 0 1 CUR -100 -500 -200 …
Remote Controller
(
obtainin
g
a meter re
g
istered in "1"
)
500msec
MTR 0 1 CUR -100 -500 -200 …
(
obtainin
g
a meter re
g
istered in "1"
)
QCMT 0 1 0
(
sto
pp
in
g
the c
y
clical
p
rocess of obtainin
g
a com
p
onent meter re
g
istered in "1"
)
QCMT OK
Mute Control
DME
SMUT 0 ON
(turning mute on)
Remote Controller
SMUT OK
MUTE 0 ON
(notifying that the mute function is turned on)
Obtaining mute condition
DME
GMUT 0
obtainin
g
mute condition
Remote Controller
GMUT OK
MUTE 0 ON
notif
y
in
g
that the mute condition is on
)
GPI OUT Control
DME
SGO 0 1 ON 2 OFF 3 ON
(turning GPI OUT CH1 on, CH2 off and CH3 on)
SGO OK
Pla
y
in
g
Back WAV file
DME
PWF 0 1
(playing back a file registered in WAV File Manager 1)
PWF OK
Stopping playback of a WAV file
DME
SWF 0
(stopping playback of a WAV file)
SWF OK
Remote Controller
Remote Controller
Remote Controller
DME Remote Control Protocol Specifications V3.1
18