User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
412
Low Pass Filter (LPF)
The low pass filter passes frequencies in the signal that are lower than a specified frequency, while
attenuating higher frequencies in the signal. There are two types of LPF components: mono channel
and stereo channel. Mono channel LPFs have one input and one output. Stereo channel LPFs have
two of each.
Double-click a component to display the component editor for it. The parameters are the same for
mono channel and stereo channel components.
Section Parameter Setting Range Function
1 Input Level - to +10 dB Sets the input signal level.
2 Phase ON/OFF Reverses the phase of the input signal.
3 LPF Frequency 20 Hz to 20 kHz Sets the cutoff frequency.
4 Slope 6 dB/Oct
12 dB/Oct
Sets the attenuation for each octave.
5 Bypass ON/OFF Turns bypass ON.
6 Output Level - to ±0 dB Sets the output signal level.
2
1
5
3 4 6
LPF component editor