User Manual

Chapter 3 Main Panel Window
DME Designer Owner’s Manual
150
User Lock
Displays and sets the panel lock status. The settings are “Unlock” and “Lock”.
Unlock: Panel not locked.
Lock: Panel locked.
The following operations cannot be performed when the panel is locked:
• Parameter changes.
• Scene recall/store.
• Scene title editing.
• Scene protect changes.
Library recall.
Misc Tab
Displays and sets parameters not provided in the other tabs.
Scene Store
Displays and sets whether scene store operations can be performed on a DME64N/24N unit. The
settings are “Enable” and “Disable”.
Enable: Scene store possible.
Disable: Scene store not possible.
Last Mem. Resume
Determines whether the scene number that was selected when the power was last turned off will
be recalled when the power is turned on, or whether the overall status of the unit when the power
was last turned off will be recalled when the power is turned on. The settings are “ON” and “OFF”.
ON: The status of the unit when the power was last turned off will be recalled.
OFF: The scene number that was selected when the unit was last turned off will be recalled.
Event Scheduler
Displays and sets whether the DME unit's Event Scheduler function is active or not. The settings
are “ON” and “OFF”.
ON: The Event Scheduler is active.
OFF: The Event Scheduler is not active.
NOTE
The default setting is “ON”, but will be set “OFF” when a file (.daf/.ddf) created by a version of DME Designer prior to
V1.2 is loaded.