User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
383
Name Function
1 Input Meter Displays the input signal level.
2 EQ Curve Displays the equalizer effect.
3 Output Meter Displays the output signal level.
Section Parameter Setting Range Function
4 Equalizer Bypass ON/OFF Bypasses each bands in the GEQ equalizer
section.
5 Gain Set by [Range]. Sets the output gain for its band.
6 GEQ ON ON/OFF Turns the GEQ ON.
7 Range ±15
±12
±6
-24
Selects the gain adjust width.
8 EQ Flat -- Returns the faders of all bands to 0dB.
9 Input Level - to +10 dB Sets the input signal level.
) Phase ON/OFF Reverses the phase of the input signal.
! HPF Frequency 20 Hz to 20 kHz Sets the HPF cutoff frequency.
@ Bypass ON/OFF Turns bypass ON.
# LPF Frequency 20 Hz to 20 kHz Sets the LPF cutoff frequency.
$ Bypass ON/OFF Turns bypass ON.
% Notch Frequency 20 Hz to 20 kHz Sets the notch filter frequency.
^ Q: 0.1 to 63.0 Sets the width of the frequency band that will
be changed by the filter.
& Bypass ON/OFF Turns bypass ON.
* Output Level - to ±0 dB Sets the signal level.
( On ON/OFF Turns output ON.
1
5
4
2
3
7
)
9
(
*
@
!
$
#
&
% ^
&
% ^
&
% ^
&
% ^
8
6
Component editor for GEQ