User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
400
Section Parameter Setting Range Function
1 Input Channels Phase ON/OFF Reverses the phase of each channel’s
input signal.
2 Gate Indicator -- When the gate is open, the light turns
green. When the gate is closed, the light
turns yellow.
3 Threshold -54 dB to ±0 dB Sets the threshold value for each gate.
4 Hold 44.1 kHz: 110 m to 2.13 s
48 kHz: 101 m to 1.96 s
88.2 kHz: 55.1 m to 1.06 s
96 kHz: 50. 6m to 981 m
Sets the gate hold time.
The setting range may vary, depending
on the operating frequency.
5 Decay 44.1 kHz: 110 m to 46 s
48 kHz: 101 m to 42.3 s
88.2 kHz: 55 m to 23 s
96 kHz: 51 m to 21.1 s
Sets the speed for closing the gate.
The setting range may vary, depending
on the operating frequency.
6 Solo ON/OFF Turns solo ON. If Solo is engaged for
even one channel, all non-Solo channels
will be muted.
7 On ON/OFF Turns ON each channel’s input.
8 Fader - to +10 dB Sets the input signal level for each
channel.
9 Master Output Gain Correct ON/OFF The output gain will be adjusted
according to the number of channels
being mixed.
) On ON/OFF Turns ON each channel’s output.
! Master - to +10 dB Sets the output signal level.