User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
428
Different numbers of channels are provided by each component variation.
Each frequency band has its own color, with Low being red, Mid being green, and so on.
Name Function
1 Library name Displays library name.
2 Crossover response (phase) Crossover phase response, color coded for
output channel.
3 Crossover response (level) Crossover level response, color coded for
each output channel.
4 Input meter Displays the input signal level.
5 Output meter Displays the output level for each band.
6 Crossover Curve Display Button Turns crossover curve display for each
output channel on or off.
Section Parameter Range Function
7 Delay Delay ON/OFF Applies delay to the crossover response.
8 PEQ PEQ ON/OFF Applies PEQ to the crossover response.
9 Navigator Input Level - to +10 dB Specifies the input signal level.
) Crossover Opens the crossover editor window.
! Delay Opens the delay editor window.
@ PEQ Opens the parametric equalizer editor
window.
# Output Level - to +10 dB Sets the output level from each output
channel.
$ Mute ON/OFF Mutes the output of each output channel.
% Limiter Opens the limiter editor window.
1 Way ALL
2 Way Low/High
3 Way Low/Mid/High
4 Way Low/Low-Mid/High-Mid/High
5 Way Sub-Low/Low/Low-Mid/High-Mid/High
6 Way Sub-Low/Low/Low-Mid/Mid/High-Mid/High