CobraNet Input and Output
The DME8i-C/DME8o-C/DME4io-C configuration window includes [CobraNet Input] and [CobraNet
Output] blocks.
CobraNet
Either double-click [CobraNet Input]/[CobraNet Output] or select [Open CobraNet Editor] from the
contextual menu that appears when a component is right-clicked to open the editor.
CobraNet Input/Output Component Editor
* Select “Disable” if you intend to make settings via the CobraNet network using the CobraNet Manager, for example. In such
cases selecting “Enable” may result in incorrect settings.
Section Name/Parameter Range Function
1 Setting from this Window Disable/Enable When “Disable” is selected settings made via
the CobraNet network take priority. When
“Enable” is selected settings made from the
DME Designer take priority.*
2 High Sampling
Mode
Input Format Double Channel
Single
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Output Format.
Output Format Double Channel
Single
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Input Format.
3 Bundle
Number
Input 0 ~ 65279 Specifies the input bundle number.
Output 0 ~ 65279 Specifies the output bundle number.
4 Serial
Channel
Rx OFF, 1 ~ 15 Specifies the serial receive channel.
Tx OFF, 1 ~ 15 Specifies the serial transmit channel.
5 Properties Bit Length Bit Off
16bit
20bit
24bit
Specifies the output bit rate.
Output is muted when “Bit Off” is selected.
6 Latency 5.33ms
2.67ms
1.33ms
Specifies the latency.
7 Advanced - Opens the “Advanced Settings” window.