User Manual

Chapter 3 Main Panel Window
DME Designer Owner’s Manual
98
“GPI” Dialog Box
When you click the [GPI] command on the [Tools] menu, the “GPI” dialog box is displayed. Sets GPI
input/output for the DME.
Names and Functions
[DME]
From the list, select the DME where you will be making settings.
Configuration
The current configuration name will be displayed.
GPI IN
The DME64N has 16 GPI IN channels, and the DME24N/DME8i-C/DME8o-C/DME4io-C has 8 GPI
IN ports.
These settings determine which DME parameters will be controlled by input received at each
individual GPI IN port. The port numbers are shown in the leftmost column.
[Function]
Specifies the function to be controlled by GPI input. Click to see a list from which you can choose
the function to be assigned to the corresponding GPI IN port.
The nine available functions are: [No Assign], [Parameter Value Edit], [Scene Change], [Scene
Increment], [Scene Decrement], [Mute], [GPI Lock], [Time Adjustment], [Play Wav File].
The [Parameter], [Min], [Max], and [Terminal] items will change according to the selected function.
GPI IN
[DME]
[Apply]
Button
[Cancel]
Button
[OK]
Button
GPI OUT