User Manual

1.2 Remote Controller Setting
The Remote Controller settings for each connection are indicated as below.
Settings for control via the REMOTE connector
Baud Rate : 38400 bps
Data : 8bit
Parity : none
Stop Bit : 1bit
Flow Control : none
Settings for control via Ethernet (the NETWORK connector; not supporting DME64N/24N V3.5 or earlier)
IP Address: Specify the IP address of the DME Satellite to be controlled.
IP Port No.: S
p
ecif
y
the IP Port No. that is set to the DME Satellite to be controlled.
1.3 DME Setting
The DME series settin
s for connection via the both connector are indicated as below.
1.3.1. DME series V3.8 or later
To dis
p
la
y
the setu
p
window
From DME Desi
g
ne
r
From the DME
p
anel dis
p
la
y
(
onl
y
for DME64N/24N
)
To set the
p
arameter values
For control via the REMOTE connector
Select "Remote
(
RS-232C
)
" to control the DME via the RS-232C connection.
Select "Remote
(
RS-422
)
" to control the DME via the RS-422 connection.
For control via Ethernet
(
the NETWORK connector
)
Select "Network".
1.3.2. DME64N/24N V3.5 or earlier
(
not su
pp
ortin
g
the control via Ethernet
)
To dis
p
la
y
the setu
p
window
From DME Desi
g
ne
r
From the DME
p
anel dis
p
la
y
To set the
p
arameter values
Select "Remote Ctrl
(
232C
)
" to control the DME via the RS-232C connection.
Select "Remote Ctrl
(
422
)
" to control the DME via the RS-422 connection.
1.3.3. DME Satellite V3.5 or earlier
To dis
p
la
y
the setu
p
window
To set the
p
arameter values
For control via the REMOTE connector
Select "Remote Ctrl
(
232C
)
" as the Remote
p
arameter to control the DME via the RS-232C connection.
Select "Remote Ctrl
(
422
)
" as the Remote
p
arameter to control the DME via the RS-422 connection.
For control via Ethernet
(
the NETWORK connector
)
Check the checkbox for
[
Remote Control via Ethernet
]
.
The DME series can be controlled from an external device via the REMOTE connector or Ethernet (NETWORK connector; not
supporting DME64N/24N V3.5 or earlier).
The DME series can be controlled from an external device via the REMOTE connector or Ethernet (NETWORK connector; not
supporting DME64N/24N V3.5 or earlier).
Hold down the [Utility] button for three seconds to show the Utility display, then press the [Utility] butto
n
re
p
eatedl
y
until the Misc
p
a
g
e is shown. On the
p
a
g
e, select the Remote
p
arameter.
After going online between DME Designer and the DME series, open the [Hardware] menu -> [Utility] -> [Misc]
p
a
g
e of DME Desi
g
ner.
Generally the IP Port No. does not have to be set. However, it needs to be changed when the network consists of
another network device than the DME series and the network device has the same IP Port No. as the DME
series. Changing the port automatically resets the network connection on the DME, which means that DME
Designer needs to be restarted.
After going online between DME Designer and the DME series, open the [Hardware] menu -> [Utility] -> [Remote]
p
a
g
e of DME Desi
g
ner, then set the DME Remote Control
p
arameter.
Hold down the [Utility] button for three seconds to show the Utility display, then press the [Utility] butto
n
re
p
eatedl
y
until the Remote
p
a
g
e is shown. On the
p
a
g
e, set the Rmt Ctrl
p
arameter.
For only the DME Satellite, set the DIP switch (leftmost) on the rear panel to "RS-232C" (up) or "RS-422" (down)
while the
p
ower is off as well. If the settin
g
is chan
g
ed, the DME Satellite needs to be restarted.
Set the DIP switch (leftmost) on the rear panel to "RS-232C" (up) or "RS-422" (down) while the power is off as
well. If the settin
g
is chan
g
ed, the DME needs to be restarted.
After going online between DME Designer and the DME series, open the [Hardware] menu -> [Utility] -> [Misc]
p
a
g
e of DME Desi
g
ner, then set the Remote
p
arameter.
Generally the IP Port No. does not have to be set. However, it needs to be changed when the network consists of
another network device than the DME series and the network device has the same IP Port No. as the DME
series. Changing the port automatically resets the network connection on the DME, which means that DME
Designer needs to be restarted.
DME Remote Control Protocol Specifications V3.1
3