Miscellaneous Setup (Misc) Page
This page includes parameters not available in any other
page.
1 Scene Store
Determines whether or not scene store operations are
allowed. This parameter can be set to “Enable” or
“Disable.”
Enable: Scene store operations are allowed.
Disable: Scene store operations are prohibited.
Edit using the “List Parameters” editing procedure
described on page 37.
2 Last Mem. Resume
This parameter displays and determines whether the
DME64N/DME24N will recall the current scene when
started up, or whether the memory contents at the time the
unit was turned off will be recalled. The possible settings
are “ON” or “OFF”.
ON: The memory contents at the time the unit was
turned off will be recalled at startup.
OFF: The current scene will be recalled at startup.
3 Event Scheduler
Determines whether an event schedule setup in the DME
Designer will be executed or not, and displays the current
status. This parameter can be set to “ON” or “OFF.”
ON: The event will be executed.
OFF: The event schedule will not be executed.
Edit using the “List Parameters” editing procedure
described on page 37.
4 Remote
Determines the [REMOTE] connector communication
mode.
Edit using the “List Parameters” editing procedure
described on page 37.
Displays the settings of the [REMOTE] terminal.
HA Control (422)
Allows remote head amp control.
Always use this setting when a remote head amp unit
(AD8HR, AD824) is connected. Also, dont change the
setting while a remote head amp is connected. Doing so
can damage the unit.
COM (232C)
Allows control of DME64N/DME24N units from AMX
and Crestron type external controllers using DME
Communication Protocol*.
COM (422)
Allows from AMX and Crestron type external controllers
via the RS-232C interface using DME Communication
Protocol*.
MIDI (232C)
Allows control of DME64N/DME24N units from
external MIDI controllers via the RS-232C interface.
MIDI (422)
Allows control of DME64N/DME24N units from
external MIDI controllers via the RS-422 interface.
Remote Ctrl (232C)
Allows control of DME64N/DME24N units from
external devices via the RS-232C interface.
Remote Ctrl (422)
Allows control of DME64N/DME24N units from
external devices via the RS-422 interface.
NOTE
The Remote setting (2) will not appear on the ICP1 control
panel display.
NOTE
See page 39 for scene store procedure.
NOTE
This setting applies to individual devices only. Even if one
DME64N/24N unit is set to “Disable,” scene store operations
will be possible via another DME64N/24N in the same device
group that is set to “Enable.”
NOTE
This parameter can be changed from the device group master
only.
1
2
3
4
NOTE
This parameter can be changed from the device group master
only.