Chapter 3 Main Panel Window
DME Designer Owner’s Manual
145
Digital Mixers With a [REMOTE] Connector
Connect the mixers [REMOTE] connector to the MY16-ES64 or similar EtherSound interface card via a
9-pin D-sub cross cable, and make the appropriate EtherSound connections between the interface
card and DME units. Use an Ethernet cable connected to the [NETWORK] connectors to make
connections between DME series units.
The port to be used for head amp control via direct serial communication with a DME unit is specified
by the [Internal HA Control] parameter in the “Remote” tab in the “Utility” dialog box (page 172).
Select “Slot 1” when the DME unit to be used for serial communication is a DME24N, “Slot 3” or “Slot
4” if it is a DME64N, or “EtherSound” if it is a DME Satellite unit. The settings for all other DME units
should be “OFF”.
Use the AVS-ESMonitor software from AuviTran to specify the EtherSound serial communication
settings for both the digital mixers interface card and the interface card installed in the serially
connected DME unit.
Serial Communication mode: Unicast for bidirectional operation.
Set the digital mixer’s interface card to “Mode 3,” and the DME unit to be used for serial
communication to “Mode 2.”
Baud Rate: 38400
In order to turn serial communication off for the interface cards installed in all other DME units, set the
Serial Communication mode to “Slave”.
NOTE
DME24N units with firmware version V3.04 or later are compatible.
You can download the AVS-ESMonitor software from the AuviTran website.
http://www.auvitran.com/
DME8i-ES
DME4io-ES
DME24N
Ethernet
EtherSound
MY16-ES64
MY16-EX64
MY16-ES64
Network
Switch
(mode 3)
(mode 2)
Digital Mixer
D-Sub 9-pin