User Manual

Chapter 3 Main Panel Window
DME Designer Owner’s Manual
175
Protocol
Displays/sets the protocol to be used for communication with devices connected via MIDI. The
available settings are: MIDI, DAW (Type1), and DAW (Type2).
MIDI: Use this setting when any MIDI device other than a general-purpose ProTools controller
(HUI protocol) or general-purpose Logic or Cubase controller (Mackie control protocol) is to be
connected.
DAW (Type1): Use this setting when a general purpose ProTools controller (HUI protocol) is to
be connected.
DAW (Type2): Use this setting when a general purpose Logic or Cubase controller (Mackie
control protocol) is to be connected.
MIDI CH
Sets the MIDI channel. This number is also used as the Parameter Change Device ID.
•[Tx]
Select the MIDI transmit channel from the list.
•[Rx]
Select the MIDI receive channel from the list.
Program Change/Control Change/Parameter Change
Sets transmit (Tx), receive (Rx), OMNI, and Echo for program change/control change/parameter
change. When ON, clicking turns this OFF. When OFF, clicking turns this ON. When OMNI is [ON]
channel messages are received regardless of the receive channel setting. When ECHO is [ON] the
input data is “echoed” (re-transmitted) via the output port that corresponds to the input port via
which it was received.
Program change, control change, and parameter change details can be set up via the “MIDI”
window [Program Change], [Control Change], and [Parameter Change] tabs, respectively.
NOTE
If the Protocol setting is changed while online, the DAW Type specified in the DAW Control dialog box will also change
accordingly.
NOTE
The following parameters are available when the Protocol parameter is set to MIDI.