SP2060 Backup
Click [SP2060 Backup] in the [Hardware] menu to open the “SP2060 Backup” dialog box. Internal
SP2060 data can be transferred to a computer for backup, and the backup data can be used to
restore multiple SP2060 units. This makes it possible to set up a single SP2060 unit, and then
distribute the settings to a group of SP2060 units.
Backup can also be carried out using the “Backup” dialog box, but the “SP2060 Backup” dialog box
has the following differences:
“SP2060 Backup” can only be used for SP2060 backup.
Data from only one SP2060 can be backed up at a time, but that data can be used to
simultaneously restore multiple SP2060 units.
Network settings are not affected when the data is restored.
[Backup] Tab
Ta rget
Displays the label and IP address of connected SP2060 units that are offline. One SP2060 unit can
be selected for backup.
[Designer <- SP2060] Button
The data is acquired from the specified SP2060 unit and saved as an SP2060 backup file (file
extension “.spb”).
NOTE
Backup files cannot be edited using DME Designer.
Backup/restore can only be carried out while offline.
Only users for whom [Edit] security is checked (enabled) can perform backup and restore operations.
If backup data is restored to an SP2060 unit running a firmware version prior to V1.3, the network settings will be changed.