[Program+Component]
Updates the DME/SP2060/ICP1 unit firmware.
1 Select [Firmware Update] [Program+Component] in the [Hardware] menu.
The folder select dialog box will be displayed.
2 Select the folder that contains the update file, then click the [OK] button.
The “Firmware Update” window will open. The names, firmware version numbers and IP
addresses of DME, SP2060 and ICP1 units in the current device group will be displayed in a list.
3 Check the DME, SP2060, or ICP1 unit you wish to update.
Clicking the checkboxes alternately turns the check mark on and off. The [Select All] button can
be used to check all DME, SP2060, and ICP1 units. The [Clear All] button removes the check
marks from all DME, SP2060, and ICP1 units.
4 When the DME, SP2060, and ICP1 units to be restored have been checked, click the
[Update] button.
The firmware update will begin.
When the restore update is complete the DME, SP2060, and ICP1 units will restart automatically.
It is also necessary to restart the DME designer.
NOTE
DME Designer cannot be used to upgrade firmware version 3.5 or earlier to version 3.8 or later, or to downgrade from
version 3.8 or later to version 3.5 or earlier (this does not apply to the SP2060 or ICP1). Contact your Yamaha dealer.
NOTE
All connected DME units are displayed in the Device field.
NOTE
If a cable is disconnected or the power is interrupted during a firmware update operation, it may not be possible to
restart the unit after the update has finished and the conditions listed below may occur. If this happens it will be
necessary to carry out the Recovery Update procedure described below.
“Recovery Update” appears on the DME64N/24N and/or ICP1 display.
The DME Satellite “ERROR” indicator lights and the channel 2 PEAK indicator flashes.
“Download Mode” appears on the SP2060 display.