SP2060 Properties
Select an SP2060 object and click [Properties] in the [Edit] menu to open the “Speaker Processor
Device Properties” window. The SP2060 properties can be edited here.
[Label] Box
Up to 100 single-byte characters or 50 two-byte characters can be entered for display on the
object. One two-byte character is equivalent to two single-byte characters. Single-byte and two-
byte characters can be mixed.
[Width] Box
Specifies the object width in pixels.
[Height] Box
Specifies the object height in pixels.
[Style]
Specifies the object style: select [Plain], [Raised], or [Sunken] from the list.
Show Scene Display and On-line Indicator
When checked the current scene number and name and on-line indicator are displayed in the zone
window.
[Label Font] Button
Specifies the label font. The “Select Font” window will appear when this button is clicked.
See “The Select Font Window” on page 264 for details on using the Select Font window.
[Label Color] Button
Specifies the color of the label characters. The “Select Color” window will appear when this button
is clicked.
NOTE
The label specified in the [Label] box will appear in the Toolkit window, the [Import] and [Export] menu commands, and
window lists. When multiple SP2060 units are used they can be given different labels for easy identification and
differentiation.