User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
396
Delay
When you click the [Delay] button for the crossover processor, it opens the delay editor window.
Here you can set the delay for each frequency band.
Parameter Setting Range Function
1
Delay ms: 0 to 500
Sample: the range depends on the Fs value.
Meter: 0 to 171.8
Feet: 0 to 563.6
Frame: the range depends on the Frame value.
Beat: the range depends on the Beat value.
Sets the delay time.
2
Level -∞ to ±0 dB Sets the output signal level for each
channel.
3
On ON/OFF Turns delay ON.
4
Delay Scale ms
Sample
Meter
Feet
Frame
Beat
Selects the units for setting the delay
time. The selected button will light up,
and the units in the [Delay] edit box
will change.
If [Beat] is selected, use the knob to
set the BPM (beats/minute).
NOTE
Delay Scale does not support the parameter link feature. Refer to “Parameter Link” on page 94 for information on parameter
linking.
1
2
3
4