User Manual

Chapter 6 Component Guide
DME Designer Owner’s Manual
499
MY8-AE96S
Right-click the block and select [Open MY-Card Editor] from the context menu to display the editor
for it.
MY16-AE/MY8-AE96/MY8-AE/MY8-AT/MY8-TD/MY16-TD/MY16-AT
Right-click the block and select [Open MY-Card Editor] from the context menu to display the editor
for it.
Parameter Setting Range Function
1
Input Format DOUBLE SPEED/
DOUBLE CHANNEL
Selects the format for 88.2/96 kHz.
2
Double Fs ON/OFF When ON the speed of the word clock from the MY
Card is doubled. Only displayed when this card is
functioning as the word clock master.
3
Output Format DOUBLE SPEED/
DOUBLE CHANNEL
Selects the format for 88.2/96 kHz.
4
Sampling Rate
Converter
ON/OFF Turns the sampling rate converter ON.
Parameter Setting Range Function
1
Input Format DOUBLE SPEED/
DOUBLE CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz. For MY8-AE96, the
setting range is Double Speed/Double Channel. For
other cards, it is Double Channel/Single.
2
Double Fs ON/OFF When ON the speed of the word clock from the MY
Card is doubled. Only for MY16-AE/MY8-AE96/MY16-
TD. When On is set for the MY8-AE96, the Input Format
is Double Channel. When Off is set, the input format is
Double Speed. Only displayed when this card is
functioning as the word clock master.
3
Output Format DOUBLE SPEED/
DOUBLE CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz. For MY8-AE96, the
setting range is Double Speed/Double Channel. For
other cards, it is Double Channel/Single.
1
3
4
2
MY8-AE96S component editor
1
3
2
Example: MY16-AE component editor