MY16-C
Right-click the block and select [Open MY-Card Editor] from the context menu to display the editor
for it.
Section Parameter Setting Range Function
1
Setting Priority Setting Priority Hardware/
Software
The MY16-C switch settings take priority when
“Hardware” is selected, and the DME Designer
settings take priority when “Software” is
selected.
2
High Sampling
Mode
Input Format DOUBLE
CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Output Format.
Double FS ON/OFF When turned ON the speed of the MY card word
clock output is doubled. Only available when
the card is set as the word clock master.
Output Format DOUBLE
CHANNEL/
SINGLE
Selects the format for 88.2/96 kHz sampling
rates.
Linked to Input Format.
3
Bundle Number Input 0 to 65279 Sets the input bundle number.
Output 0 to 65279 Sets the output bundle number.
4
Serial Channel Rx OFF, 1 - 16 Sets the serial channel for the receive side.
Tx OFF, 1 - 16 Sets the serial channel for the send side.
5
Properties Bit Length Bit Off
16 bit
20 bit
24 bit
Sets the bit rate for output. Mutes the signal if
[Bit Off] is set.
6
Latency 5.33 ms
2.67 ms
1.33 ms
Sets the delay.
NOTE
The parameters will not link immediately when Setting Priority is switched.
Please edit another parameter after switching Setting Priority.
1
2
3
4
5
6
MY16-C component editor