User Manual

7
Notes for DME64N/DME24N Version 1.2
Recovering The DME64N/24N program update has failed. Restoring
the previous program. Do NOT turn off the power while
this display is on the screen.
Retry the program update. If the update is still
unsuccessful after several retries, a malfunction is likely.
Contact a Yamaha electric sound service outlet listed at
the end of this manual (page 79).
Saving Failed Cannot save settings. Since this is likely to be a device failure, contact a Yamaha
electric sound service outlet listed at the end of this
manual (page 79).
Saving HA Info Saving head amp information. Do NOT turn off the power
while this display is on the screen.
Saving Setup Info Saving information (except head amp information) that is
set in the utility screen. Do NOT turn off the power while
this display is on the screen.
Scene Recalling Recalling a scene.
Scene Storing Storing a scene. Do NOT turn off the power while this
display is on the screen.
SLOT1 Sync Err The word clock input from Slot1 is not synchronized with
the DME64N/24N word clock.
Recheck the settings for using the word clock that
synchronizes the DME64N/24N and external devices.
SLOT2 Sync Err The word clock input from Slot2 is not synchronized with
the DME64N word clock.
Recheck the settings for using the word clock that
synchronizes the DME64N and external devices.
SLOT3 Sync Err The word clock input from Slot3 is not synchronized with
the DME64N word clock.
SLOT4 Sync Err The word clock input from Slot4 is not synchronized with
the DME64N word clock.
Slots Overloaded The electric current being consumed by cards currently
installed in the slots exceeds the specified value.
This combination cannot be used. Check the combination
of cards that are currently installed.
Store Disable Scene storing is currently prohibited in the settings. This prohibition may have been set by the administrator to
prevent unexpected data changes caused by erroneous
user operations.
Change the setting by going to the Misc page of the utility
screen and changing the setting for Scene Store to
“Enable.”
WCLK Unlocked A valid word clock is not being input or cannot be
detected.
Recheck connections and internal settings related to the
word clock.
Zone Sync Err Data from the wrong zone has been input or data has not
been input.
Use DME Designer to resend the data.
NOTE
For information about updated CD-ROM versions to be released in the future, contact the store where you purchased the device, or contact
Yamaha customer service using the contact information at the end or your “DME64N/24N Owner’s Manual.”
Message Content Corrective Action