User Manual

30/34
This indicator will appear.
Press to activate the DME monitor in the PM5D CUE bus.
Choose the name of the
component to be edited here.
In the DME CONTROL SETUP screen, click ‘CONNECT’ and
select the type of component to be edited here.
DME scenes can be recalled from here. And scenes can be
stored (but they can only be overwritten if they already exist:
new scenes cannot be created).
So one tip is to create several ‘spare’ scenes containing the
initial data, which can be overwritten if needed.
Click here to control the GEQ or MATRIX mixer with the DCA faders
(or press SHIFT+FADER MODE on PM5D).
PM5D & DME24N with MY16-C/MY16-CII / Remote Control & Bi-directional Audio (Using MY16-C/MY16-CII)
Control and Monitoring
In the Monitor Out box of DME Designer (in the Tools menu of
the main window), select a spare MY16-C/MY16-CII output to
link the DME monitor to the PM5D CUE bus.
For PM5D, in the DME CONTROL-SETUP screen, select the
same cascade port as the MONITOR PORT, so you can hear the
DME monitor in the PM5D CUE bus.