Filter Type
Various types of curves are available for changing the level. Click the [Type] button and select the
type from the menu.
PEQ
This is a general parametric equalizer.
•L. SHELF (Low Shelving)
There is no sound attenuation at low frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the higher frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
H.SHELF (High Shelving)
There is no sound attenuation at high frequencies. The sound is attenuated at a constant rate
from the cutoff frequency towards the lower frequencies. The attenuation rate per octave can
be set to [6 dB/Oct] or [12 dB/Oct].
HPF
This is a high-pass filter (Q=0.7). Attenuates the low frequencies with a gentle curve (12 dB/
Oct).
LPF
This is a low-pass filter (Q=0.7). Attenuates the high frequencies with a gentle curve (12 dB/
Oct).
Name Function
1 EQ Curve Displays the equalizer effect.
You can change the parameter by dragging
the control point with the mouse.
Section Parameter Setting Range Function
2 Input Level - to +10 dB Sets the input signal level.
3 Phase ON/OFF Reverses the phase of the input signal.
4 Equalizer Type PEQ
L.SHELF 6 dB/Oct
L.SHELF 12 dB/Oct
H.SHELF 6 dB/Oct
H.SHELF 12 dB/Oct
HPF
LPF
Select the filter type from the menu.
5 Q 0.1 to 16.0 Sets the band width for each frequency
band.
6 Frequency 20 Hz to 20 kHz Sets the frequency for each band.
7 Gain -18 dB to +18 dB Sets the level of the frequency that will be
changed.
8 Bypass ON/OFF Turns ON bypass for each band.
9 Equalizer PEQ ON ON/OFF Turns the PEQ ON
) Output Level - to ±0 dB Sets the output signal level.
! On ON/OFF Turns output ON.