User`s manual

60
CHAPTER2 PROFIBUS Unit
1) Press
F3
(SYS) on the initial screen.
2) Press
F4
(next) to switch to the func-
tion display. When the function display
appears, then press
F2
(OPT).
3) Press
F4
(next) to switch the function
display. To directly send the external par-
allel I/O input to the master sequencer
(PLC) press
F1
(DSO). To directly
send the input from the master sequencer
(PLC) to the external parallel I/O, press
F2
(SDO).
4) This is the screen when
F1
(DSO)
was selected above in step 3). The DI15 -
DI0 current settings appear on the screen
from the left side. Here, “0” indicates
normal status, and “1” indicates a emu-
lated serialization setting.
To change a setting, press the function key
displaying the DI No. you want to set. If
the DI No. you want to set is not shown,
just press the
F4
(next) as many times
as needed to select DI3 - DI15.
5) This is the screen when
F2
(SDO)
was selected above in step 3). The DO12
- DO0 current settings appear on the
screen from the left side. Here, “0” indi-
cates normal status, and “1” indicates a
emulated serialization setting.
To change a setting, press the function key
displaying the DI No. you want to set. If
the DI No. you want to set is not shown,
just press the
F4
(next) as many times
as needed to select DO3 - DO12.
6) Press the
ESC
key to return to the screen
in step 3).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE2OPT 3UTL 4next
[SYS-OPT]
select menu
1D
SO2S
DO3 4next
[SYS-OPT-D
SO]
DI 00001111 00000000
DI
SO connect
1DI0 2DI1 3DI2 4next
[SYS-OPT-S
DO]
DO 00011 00000000
SI
DO connect
1DO0 2DO1 3DO2 4next
[SYS-OPT]
select menu
1D
SO2S
DO3 4next