CHAPTER2 Ethernet Unit
■ Example 3
In this example, the control PC and the controllers are separated from each other.
* The 10BASE-5 cable has a maximum length of 500 meters. However, this distance can
be extended to a maximum of 2.5 kilometers by connecting cables together and using
repeaters, etc.
PC Controller
Terminator Terminator
Transceiver (MAU)
10BASE-5 cable
Transceiver (MAU)
Transceiver cable (AUI cable)
Transceiver cable (AUI cable)
HUB with 10BASE-5 connector
HUB with 10BASE-5 connector
PC
Controller 1
Controller 2
Controller 3
IP address
192.168.0.2
192.168.0.3
192.168.0.4
192.168.0.5
Subnet mask
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
Gateway
192.168.0.1
192.168.0.1
192.168.0.1
192.168.0.1
System setup example