ENGINE ASSEMBLY AND ADJUSTMENTS
5-58
2
1
8. Connect:
Servomotor unit lead
Cables (Y.P.V.S.)
(to power valve pulley)
9. Install:
Pulley (power valve)
10. Adjust:
Y.P.V.S. cables
Refer to the “Y.P.V.S. CABLE ADJUST-
MENT” section in chapter 3.
NOTE:
Before adjusting the Y.P.V.S. cables, turn the
main switch “ON” and operate the Y.P.V.S.
motor.
11. Install:
Pulley cover (Power valve)
12. Adjust:
Clutch cable free play
Refer to the “CLUTCH ADJUSTMENT”
section in chapter 3.
Bolt (Power valve pulley):
10Nm (1.0 m•kg, 7.2 ft•lb)
Bolt (Pulley Cover):
7 Nm (0.7 m•kg, 5.1 ft•lb)
1
1
1