COOL
THERMOSTATIC VALVE AND RADIATOR
6-12
FULL
LOW
2. Install:
• Radiator
3. Apply grease to the O-ring
4. Install:
• O-ring
Water outlet pipe
ss
WARNING
Always use a new O-ring
5. Fill:
• Radiator
Reservoir tank (Radiator)
Refer to the “COOLANT REPLACEMENT”
section in chapter 3.
6. Inspect:
Cooling system
Decrease of pressure (leaks)

Repair as
required
Screw (Water Outlet Pipe):
8 Nm (0.8 m·kg; 5.8 ft·lb)
2
1
Bolt(Radiator):
8 Nm (0.8 m·kg; 5.8 ft·lb)