Service manual

ELEC
IGNITION SYSTEM
8-10
EAS00749
5. Main switch
Disconnect the main switch coupler and
lead from the wireharness (red).
Connect the pocket tester ( 100) to the
main switch.
Positive tester probe

red Lead
Negative tester probe

brown-blue
Terminal
Turn the main switch to “ON” and “OFF”.
Check the main switch for continuity.
Switch Good Bad
position condition condition
OFF XX
ON X X
PARK X X
:Continuity X: No continuity
EAS00750
6. “ENGINE STOP” switch
Disconnect the “ENGINE STOP” switch
leads from the wireharness.
Connect the pocket tester ( 100) to the
“ENGINE STOP” switch.
Positive tester probe

black/white Lead
Negative tester probe

Black Lead
Turn the “ENGINE STOP” switch to “OFF”
and “RUN”.
• Check the “ENGINE STOP” switch for con-
tinuity.
Switch Good Bad
position condition condition
OFF X X
ON XX
:Continuity X: No continuity
Is the engine stop switch OK?
Replace the main
switch.
YES
NO
Replace the hand-
lebar switch.
YES
NO