Service manual
ELEC
SIGNAL SYSTEM
8-29
3. “TURN” switch
• Disconnect the “TURN” switch (Left hand-
lebar switch) coupler from the wire har-
ness.
• Connect the pocket tester (Ω 1) to the
“TURN” switch.
When turning “TURN”” switch to “R”:
Positive tester probe
Brown/White
Lead
Negative tester probe
Dark green
Lead
When turning “TURN” switch to “L”:
Positive tester probe
Brown/White
Lead
Negative tester probe
Chocolate
Lead
• Turn the “TURN” switch to the “R” and “L”.
• Check the “TURN” switch for continuity.
Switch Good Bad
position condition condition
R XX
L XX
:Continuity X: No continuity
• Is the “TURN” switch OK?
4. Voltage
• Disconnect the flasher relay coupler
from the wire harness.
• Turn the main switch to “ON”.
• Turn the “TURN” switch to the “R” or “L”.
• Connect the pocket tester (DC20V) to the
flasher relay coupler.
Positive tester probe
Brown
Terminal
Negative tester probe
Frame ground.
• Check the flasher votage.
Flasher voltage
12.0 V
• Is the flasher relay OK?
EAS00795
5. Wiring
• Check the entire signal system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
• Is the signaling system’s wiring properly
connected and without defects?
Replace the
“TURN” switch.
YES
NO
Replace the flasher
relay.
YES
NO
Properly connect or
repair the signaling
system’s wiring.
Check the condition
of each of the sig-
naling system’s cir-
cuits.
Refer to “CHEC-
KING THE SIGNA-
LING SYSTEM”.
YES