Service manual

ELEC
SIGNAL SYSTEM
8-29
3. “TURN” switch
Disconnect the “TURN” switch (Left hand-
lebar switch) coupler from the wire har-
ness.
Connect the pocket tester ( 1) to the
“TURN” switch.
When turning “TURN”” switch to “R”:
Positive tester probe

Brown/White
Lead
Negative tester probe

Dark green
Lead
When turning “TURN” switch to “L”:
Positive tester probe

Brown/White
Lead
Negative tester probe

Chocolate
Lead
• Turn the “TURN” switch to the “R” and “L”.
Check the “TURN” switch for continuity.
Switch Good Bad
position condition condition
R XX
L XX
:Continuity X: No continuity
Is the “TURN” switch OK?
4. Voltage
Disconnect the flasher relay coupler
from the wire harness.
Turn the main switch to “ON”.
Turn the “TURN” switch to the “R” or “L”.
Connect the pocket tester (DC20V) to the
flasher relay coupler.
Positive tester probe

Brown
Terminal
Negative tester probe

Frame ground.
Check the flasher votage.
Flasher voltage
12.0 V
Is the flasher relay OK?
EAS00795
5. Wiring
Check the entire signal system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
Is the signaling system’s wiring properly
connected and without defects?
Replace the
“TURN” switch.
YES
NO
Replace the flasher
relay.
YES
NO
Properly connect or
repair the signaling
system’s wiring.
Check the condition
of each of the sig-
naling system’s cir-
cuits.
Refer to “CHEC-
KING THE SIGNA-
LING SYSTEM”.
YES
NO