Service manual

ELEC
SIGNAL SYSTEM
8-36
1. “HORN” switch
Disconnect the “HORN” switch (Left hand-
lebar switch) couplers from the wire har-
ness.
Connect the pocket tester ( 1) to the
“HORN” switch.
Positive tester probe

Pink Terminal
Negative tester probe

Black Terminal
Check the “HORN” switch for continuity.
Switch Good Bad
position condition condition
“HORN” switch XX
is pushed
“HORN” switch
X X
is not pushed
:Continuity X: No continuity
Is the oil level switch OK?
HORN DOES NOT SOUND, WHEN PUS-
HING “HORN” SWITCH
2. Voltage
Connect the pocket tester (DC20V) to the
horn terminal.
Positive tester probe

Brown
Terminal
Negative tester probe

Frame ground.
Turn the main switch to “ON”.
Check the horn voltage.
Horn voltage
12.0 V
EAS00795
3. Wiring
Check the entire signal system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
Is the signaling system’s wiring properly
connected and without defects?
Replace the
“HORN” switch.
YES
NO
Properly connect or
repair the signaling
system’s wiring.
Check the condition of
each of the signaling
system’s circuits. Refer
to “CHECKING THE
SIGNALING SYSTEM”.
YES
NO