Data List
2.3 Channel Mode
AlltypesofChannelModemessagearereceived,butnonearetransmitted.
2.3.1 All Sound Off (120)
Upon receipt of an All Sound Off message, the DTX-MULTI12 mutes all voices
currentlyplayingonthecorrespondingchannel.
2.3.2 Reset All Controllers (121)
Upon receipt of a Reset All Controllers message, the DTX-MULTI12 resets the
following controllers to their initial values: Pitch Bend, Modulation, Expression,
Hold1,Sostenuto,andRPNnumber.
2.3.3 All Note Off (123)
Upon receipt of an All Note Off message, the DTX-MULTI12 mutes all notes
currentlyplayingonthecorrespondingchannel.IfHold1orSostenutoisturned
on,however,mutingwillnottakeplaceuntilsaidcontrolleristurnedoff.
2.3.4 Omni Off (124)
Upon receipt of an Omni Off message, the DTX-MULTI12 acts in the same way as
ifanAllNotesOffmessagehadbeenreceived.
2.3.5 Omni On (125)
Upon receipt of an Onmi On message, the DTX-MULTI12 acts in the same way as
ifanAllNotesOffmessagehadbeenreceived.
2.3.6 Mono (126)
Upon receipt of a Mono message, the DTX-MULTI12 acts in the same way as if an
AllSoundOffmessagehadbeenreceived.
2.3.7 Poly (127)
Upon receipt of a Poly message, the DTX-MULTI12 acts in the same way as if an
AllSoundOffmessagehadbeenreceived.
2.4 Program Change
ProgramChangemessagesaretransmittedandreceived.
• IftheRcvPCparameterontheUTILITYsettingarea’sProgramChangeReceive
page(UTIL6-2)issetto“off”,ProgramChangemessageswillnotbereceived.
• IftheRcvPC10chparameterontheUTILITYsettingarea’sChannel-10Program
ChangeReceivepage(UTIL6-3)issetto“off”,ProgramChangemessageson
MIDIchannel10willnotbereceived.
• IfthePCparameterontheMIDIsettingarea’sProgramChangepage(MIDI3-
4)issetforaspecickit,aProgramChangemessagewiththecorresponding
numberwillbesentwheneverthatkitisselected.
• IftheMessageTypeparameterontheMIDIsettingarea’sSelectMessageType
page(MIDI1)issetto“PC”foraspecicpad,aProgramChangemessage
with the number specified by the PC parameter on the Program Change page
(MIDI1-1)will,uponstrikingofthatpad,besentviatheMIDIOUTconnectorbut
nottotheinternaltonegenerator.
• IfthePCparameteronthePATTERNsettingarea’sBankSelectpage(PTN3-4)
is set for a specific pattern, a Program Change message with the corresponding
numberwillbesentwheneverthatpatternisselected.
2.5 Pitch Bend
PitchBendmessagesaretransmittedandreceived.
• If,withintheKITsettingarea,theHHFuncparameterontheHi-hatFunction
page(KIT7-3)issetto“MIDI”andtheHHMIDITypeparameterfromtheHi-hat
MIDITypepage(KIT7-5)issetto“PBup”or“PBdwn”,PitchBendmessageswill
besentwhenthehi-hatcontrollerispressed.
2.6 Channel Aftertouch
ChannelAftertouchmessagesaretransmittedbutnotreceived.
• If,withintheKITsettingarea,theHHFuncparameterontheHi-hatFunction
page(KIT7-3)issetto“MIDI”andtheHHMIDITypeparameterfromtheHi-hat
MIDITypepage(KIT7-5)issetto“AT”,ChannelAftertouchmessageswillbe
sentwhenthehi-hatcontrollerispressed.
2.7 Polyphonic Aftertouch
PolyphonicAftertouchmessagesaretransmittedandreceived.
The PolyAfter parameter on the UTILITY setting area’s Polyphonic Aftertouch
Statuspage(UTIL6-4)mustbesetto“on”fortransmissionandreceptionof
PolyphonicAftertouchmessages.Insuchacase,notesassignedtoapadare
sent with a polyphonic aftertouch value of 127 when the pad is held and with a
polyphonicaftertouchvalueof0whenitisreleased.
3. System Exclusive Messages
The DTX-MULTI12 only receives system exclusive messages having an identical
device number to that set on the UTILITY setting area’s Device Number page
(UTIL6-12).
3.1 Universal Non-Real Time
3.1.1 General MIDI System On
$F0 $7E $7F $09 $01 $F7
GeneralMIDISystemOnmessagesaretransmittedandreceived.
3.1.2 Identity Request
$F0 $7E $0n $06 $01 $F7
“n”representsthedevicenumber.Uponreceiptofthismessage,theDTX-
MULTI12transmitsanIdentityReplymessage.IdentityRequestmessagesare
receivedbutnottransmitted.
3.1.3 Identity Reply
$F0 $7E $7F $06 $02 $43 $00 $41 $3A $06 $00 $00 $00 $7F $F7
IdentifyReplymessagesaretransmittedbutnotreceived.
3.2 Universal Real Time
3.2.1 MIDI Master Volume
$F0 $7F $7F $04 $01 $XX $mm $F7
$XXisignored.$mmrepresentsthevolumedata.MIDIMasterVolumemessages
arereceivedbutnottransmitted.
3.3 Parameter Change
3.3.1 XG System On
$F0 $43 $1n $4C $00 $00 $7E $00 $F7
“n”representsthedevicenumber.UponreceiptofanXGSystemOnmessage,
the DTX-MULTI12 acts in the same way as if a General MIDI System On message
hadbeenreceived.XGSystemOnmessagesarereceivedbutnottransmitted.
4. System Common Messages
4.1 Song Select
$f3 $nn
“nn”representsthesongnumber.SongSelectmessagesarereceivedbutnot
transmitted.
5. System Real Time Messages
SystemRealTimemessagesaretransmittedandreceived.
5.1 Timing Clock
If the MIDI Sync parameter on the UTILITY setting area’s MIDI Sync page is set
to “ext” or “auto”, playback will be synchronized with Timing Clock messages
receivedfromanexternalMIDIdevice.
5.2 Start, Continue & Stop
If the SeqCtrl parameter on the UTILITY setting area’s Sequencer Control page
(UTIL6-8)issetto“off”,theDTX-MULTI12willneithertransmitnorreceiveStart,
ContinueandStopmessages.
IftheMessageTypeparameterfromtheSelectMessageTypepage(MIDI1)isset
to “strt”, “cont”, or “stop” for a specific pad, a Start, Continue, or Stop message
will, upon striking of that pad, be sent via the MIDI OUT connector but not to the
internaltonegenerator.
5.3 Active Sensing
Reception: If, following receipt of an Active Sensing message, no subsequent
MIDI data is received for approximately 300 milliseconds, the DTX-MULTI12 will
muteallvoicescurrentlyplaying.
Transmission: The DTX-MULTI12 regularly transmits Active Sensing messages at
intervalswithinapproximately300milliseconds.
MIDI Data Format