User Manual

DTX900 Data List
17
Effect Parameter List
[2] 2 MODULATOR
No. Parameter Range
1 LFO Speed 0.0Hz − 39.7Hz
2 AM Depth 0 − 127
3 PM Depth 0 − 127
4 Feedback Level -63 − +63
5 Delay Offset 0.0ms − 50.0ms
6 − 9 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
10 Dry/Wet Balance D63>W − D=W − D<W63
11 EQ Mid Frequency 100Hz − 10.0kHz
12 EQ Mid Gain -12dB − +12dB
13 EQ Mid Width 0.1 − 12.0
14
15 Input Mode mono/stereo
16
[3] SPX CHORUS
No. Parameter Range
1 LFO Speed 0.0Hz − 39.7Hz
2 LFO Depth 0 − 127
3 Feedback Level -63 − +63
4 Delay Offset 0.0ms − 50.0ms
5
6 − 9 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
10 Dry/Wet Balance D63>W − D=W − D<W63
11 EQ Mid Frequency 100Hz − 10.0kHz
12 EQ Mid Gain -12dB − +12dB
13 EQ Mid Width 0.1 − 12.0
14
15 Input Mode mono/stereo
16
[4] SYMPHONIC
No. Parameter Range
1 LFO Speed 0.0Hz − 39.7Hz
2 LFO Depth 0 − 127
3 Delay Offset 0.0ms − 50.0ms
4
5
6 − 9 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
10 Dry/Wet Balance D63>W − D=W − D<W63
11 EQ Mid Frequency 100Hz − 10.0kHz
12 EQ Mid Gain -12dB − +12dB
13 EQ Mid Width 0.1 − 12.0
14
15
16
[5] ENSEMBLE DETUNE
No. Parameter Range
1 Detune -50cent − +50cent
2 Initial Delay Lch 0.0ms − 50.0ms
3 Initial Delay Rch 0.0ms − 50.0ms
4 Spread 0 − 63
5
6
7
8
9
10 Dry/Wet Balance D63>W − D=W − D<W63
11 − 14 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
15
16
Category - FLANGER & PHASER
[1] FLANGER
No. Parameter Range
1 Speed 0.04Hz − 10.0Hz
2 Manual 0 − 127
3 Depth 0 − 127
4 Feedback 0 − 127
5 Type 1 − 3
6 Spread 0 − 127
7 Mix 0 − 127
8
9
10
11
12
13
14
15
16
[2] CLASSIC FLANGER
No. Parameter Range
1 LFO Speed 0.0Hz − 39.7Hz
2 LFO Depth 0 − 127
3 LFO Wave Triangle, Sine, Random
4 Delay Offset 0.09ms − 36.21ms
5 Feedback Level -100 − +100%
6 − 9 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
10 Dry/Wet Balance D63>W − D=W − D<W63
11 EQ Mid Frequency 100Hz − 10.0kHz
12 EQ Mid Gain -12dB − +12dB
13 EQ Mid Width 0.1 − 12.0
14 Modulation Phase -180 − +180
15 Feedback High Damp 0.1 − 1.0
16 Analog Feel 0 − 10
[3] TEMPO FLANGER
No. Parameter Range
1 LFO Speed 16th − 4thx16
2 LFO Depth 0 − 127
3 Feedback Level -63 − +63
4 Delay Offset 0.0ms − 50.0ms
5 LFO Phase Reset off(free run), Key On Reset, SEQ Start Reset
6 − 9 : Same as the parameters shaded in gray in CROSS DELAY on page 15.
10 Dry/Wet Balance D63>W − D=W − D<W63
11 EQ Mid Frequency 100Hz − 10.0kHz
12 EQ Mid Gain -12dB − +12dB
13 EQ Mid Width 0.1 − 12.0
14 LFO Phase difference -180deg − +180deg
15
16
[4] DYNAMIC FLANGER
No. Parameter Range
1 Sensitivity 0 − 127
2 Delay Offset 0 − 127
3 Feedback Level -63 − +63
4 Attack Time 0.3ms − 227ms
5 Release Time 2.6ms − 2171ms
6 Release Curve 0 − 127
7 Direction up, down
8 Dyna Threshold Level 0 − 127
9 Dyna Level Offset 0 − 127
10 Dry/Wet Balance D63>W − D=W − D<W63
11
12
13 − 16 : Same as the parameters shaded in gray in CROSS DELAY on page 15.