User Manual

TRIGGER ReferenceKITMIDI VOICEUTILITY WAVEPATTERN
UTILITY Setting Area (UTIL)
Owner’s Manual 91
1 MIDI synchronization (MIDISync)
Use this parameter to specify whether patterns and the click
track are to play at the tempo set for the DTX-MULTI 12 or
are to be synchronized with external MIDI devices based on
MIDI Clock messages (i.e., F8 Timing Clock) received from
them.
int ........ Patterns and the click track will play at the current
DTX-MULTI 12 tempo setting. Use “int” when this
instrument is to be used alone or as the master
clock source for other equipment.
•ext........ The DTX-MULTI 12 will be synchronized with
MIDI Clock messages received via MIDI. Use
“ext” when an external MIDI device is to be used as
the master clock source for synchronized playback.
auto...... MIDI Clock messages received via MIDI will be
prioritized over the DTX-MULTI 12’s current
tempo. In other words, playback will be synchro-
nized to MIDI Clock messages whenever they are
received, and the internal tempo will be used in all
other cases.
In order to successfully synchronize the DTX-MULTI 12 whenever this
parameter is set to “ext” or “auto”, the connected external MIDI device
or computer must be setup to send MIDI Clock messages.
1 Clock out
Use this parameter to enable (“on”) or disable (“off”) the
sending of MIDI Clock messages (i.e., F8 Timing Clock) via
the MIDI OUT connector.
1 Sequencer control (SeqCtrl)
Use this parameter to specify whether or not System Realtime
messages (i.e., FA Start, FB Continue, and FC Stop) will be
sent and received via MIDI.
•off.........System Realtime messages are neither sent nor
received.
•in..........System Realtime messages are received but not
sent.
out ........System Realtime messages are sent but not
received.
in/out....System Realtime messages are sent and received.
If “strt”, “cont”, or “stop” has been set on the MIDI Message page
(MIDI1), the SeqCtrl setting 1 will have no effect and the respective
message (i.e., FA Start, FB Continue, or FC Stop) will be output.
1 MIDI IN/OUT
Use this parameter to specify whether the exchange of MIDI
messages with external devices is to be performed via the
MIDI connectors or the USB TO HOST port.
1 MIDI Thru port (ThruPort)
When the DTX-MULTI 12 receives MIDI messages from a
computer connected via USB, it can relay those messages
received via a specific port to the MIDI OUT connector so
that they can be output to other external MIDI devices. Use
this parameter to specify that port.
UTIL6-6 MIDI Sync page
Settings int, ext, or auto
UTIL6-7 Clock Out page
Settings off or on
UTIL6-6≥≥≥<MIDI>
≥MIDI≥Sync=int
1
NOTE
UTIL6-7≥≥≥<MIDI>
≥≥ClockOut=on
1
UTIL6-8 Sequencer Control page
Settings off, in, out, or in/out
UTIL6-9 MIDI In/Out page
Settings MIDI or USB
UTIL6-10 MIDI Thru Port page
Settings 1 or 2
UTIL6-8≥≥≥<MIDI>
≥SeqCtrl=in/out
1
NOTE
UTIL6-9≥≥≥<MIDI>
MIDI≥IN/OUT=MIDI
1
UTIL6-10≥≥<MIDI>
≥≥≥ThruPort=1
1