CONNECTION NOTES
9 Avoid connecting the generator to commercial
power outlet.
9 Avoid connecting the generator in parallel with any
other generator.
1 Correct
2 Incorrect
AE00091
CONNECTION
Before the generator can be connected to a build-
ings electrical system, a licensed electrician must
install an isolation (transfer) switch in the build-
ings main fuse box. The switch is the connection
point for generator power and allows selection of
generator or main line power to the building. This
will prevent the generator from charging the main
power line (backfeeding) when the main power
supply has failed or has been turned off for line
repair. Backfeeding can electrocute or injure line
maintenance personnel. Also, generator and build-
ing electrical system damage can occur when nor-
mal operating power returns if unit is used without
an isolation switch.
WARNING
AE00086
EXTENSION CORD NOTES
9 Extension cords should be protected by a tough
flexible rubber sheath (IEC 245) or the equivalent
to withstand mechanical stresses.