Product Manual

4-7
Operation
Application range
When using the generator, make sure the total load is within rated output of a generator.
Otherwise, generator damage may occur.
TIP
“–” means below.
Application wattage indicates when each device is used by itself.
The simultaneous usage of AC and DC power is possible but total wattage should not
exceed the rated output.
EX:
The overload indicator light comes on when electricity over the rated output is required
by the connected electrical devices, or when the inverter control unit overheats.
AC
DC (Accessory
socket)
Power factor 1 0.8–0.95
0.4–0.75
(Efficiency 0.85)
Rated voltage 12 V
Rated current 3 A
–1800 W –1440 W –612 W
Generator rated output 1800 VA
Frequency Power factor
AC
1.0 –1764 W
0.8 –1404 W
DC 36 W (12 V/3 A)