Service manual

69J1D11
2-8
1
2
3
4
5
6
7
8
9
Fuel control system
Fuel injector resistance
(*1)
at 20 °C (68 °F)
14.015.0
Starter motor
Type Sliding gear
Output kW 1.4
Cranking time limit Second 30
Brushes
Standard length mm (in) 15.5 (0.61)
Wear limit mm (in) 9.5 (0.37)
Commutator
Standard diameter mm (in) 29.0 (1.14)
Wear limit mm (in) 28.0 (1.10)
Mica
Standard undercut mm (in) 0.50.8 (0.020.03)
Wear limit mm (in) 0.2 (0.01)
Charging system
Fuse A 5, 20, 30
Stator coil output peak voltage
(G G)
at cranking (unloaded) V 10
at 1,500 r/min (unloaded) V 42
at 3,500 r/min (unloaded) V 93
(G/W G/W)
at cranking (unloaded) V 9.0
at 1,500 r/min (unloaded) V 34
at 3,500 r/min (unloaded) V 78
Stator coil resistance
(*1)
(G G)
0.280.42, 0.240.36
(G/W G/W)
0.240.36, 0.200.31
Rectifier Regulator output
peak voltage (R B, R/Y B)
at 1,500 r/min (unloaded) V 13
at 3,500 r/min (unloaded) V 13
(*1)
The figures are for reference only.
Item Unit
Model
F200TR LF200TR F225TR LF225TR
Maintenance specifications