Service manual

5-104
E
POWR
THERMOSTAT
SERVICE POINTS
Thermostat inspection
1. Check:
Thermostat 1
Does not open at 5060 °C (123
141 °F) Replace.
1 Thermostat
2 Thermometer
3 Water
4 Container
È Fully closed
É Fully open
NOTE:
If the accuracy of the thermostat is in doubt,
replace it. A faulty thermostat could cause seri-
ous overheating or over cooling.
Checking steps:
Suspend the thermostat in a container
filled with water.
Slowly heat the water.
Place a thermometer in the water.
While stirring the water, observe the ther-
mostat and thermometers indicated tem-
perature.
1
3
2
4
2. Check:
Thermostat housing cover
Thermostat housing
Cracks/damage Replace.
3. Check:
Cooling system
Leaks Repair or replace any faulty
part.
Thermostat installation
1. Install:
Thermostat housing 1
Thermostat 2
Thermostat housing cover