THERMOSWITCH (ENGINE)
1. Check:
Thermoswitch (engine) continuity
(at the specified temperature)
Out of specification
Replace.
1
No continuity
È
Temperature
2
Continuity
É
Time
THERMOSWITCH (EXHAUST)
1. Check:
Thermoswitch (exhaust) continuity
(at the specified temperature)
Out of specification
Replace.
1
No continuity
È
Temperature
2
Continuity
É
Time
Thermoswitch (engine) continuity
temperature:
a
8490 °C (183194 °F)
b
7084 °C (158183 °F)
Checking steps:
Suspend the thermoswitch (engine) in a
container filled with water.
Place a thermometer in the water.
Slowly heat the water.
Measure the continuity when the speci-
fied temperature is reached.
Thermoswitch (exhaust)
continuity temperature:
a
94100 °C (201212 °F)
b
8094 °C (176201 °F)
Checking steps:
Suspend the thermoswitch (exhaust) in a
container filled with water.
Place a thermometer in the water.
Slowly heat the water.
Measure the continuity when the speci-
fied temperature is reached.