Service manual

7-34
E
+
ELEC
STARTING SYSTEM
STARTER RELAY
1. Inspect:
Brown lead terminal
Black lead terminal
Loose
Tighten.
2. Check:
Starter relay
Faulty
Replace.
Checking steps:
Connect the tester leads between the
starter relay terminals as shown.
Connect the brown lead terminal to the
positive battery terminal.
Connect the black lead terminal to the
negative battery terminal.
Check that there is continuity between
the starter relay terminals.
Check that there is no continuity after the
brown or black lead is removed.
Br
B