Service manual

9-50
E
TRBL
ANLS
TROUBLESHOOTING
TROUBLESHOOTING
Error content Cause Action
Communication cable
related error occurs
Communication cable is discon-
nected.
Connect communication cable
between the computers commu-
nication port and 3-pin communi-
cation coupler of the watercraft.
Battery is disconnected from the
watercraft.
Connect battery to watercraft.
The battery voltage is below 12 V. Connect battery of 12 V or higher.
Application does not
start
The hardware does not meet the
requirements to operate this
application.
Use a computer that meets the
specified hardware requirements.
YDIS.exe is not installed in appli-
cation directory.
If YDIS.exe is not found in the
application directory, install the
application again.
Other application (Service tool) is
already in operation.
Quit the application in operation,
since two applications (Service
tool) cannot be operated simulta-
neously.
Application related error
occurs
Error message Program file or
Database file is not installed
properly. Please install again. is
displayed.
Install program file or database
file again.
Database related error
occurs
Error message Database files
are not installed properly. Please
update again. is displayed.
Update database again.
Error message System file not
found ######.###. is displayed.
The database is not applicable to
communication with ECM.
Update database to correspond
to ECM.
Incorrect fonts on
screen
The computer language does not
correspond to the application.
Use a computer that operates the
required operating system.
When executing the sta-
tionary test or active test
the test cannot be
ended even if the Can-
cel is clicked.
Execute and Cancel buttons have
been clicked more than neces-
sary, and the ECM or PC does
not operate properly.
Turn off your PC.
Push the engine stop switch and
reset the ECM.