Service manual

3-25
E
INSP
ADJ
ELECTRICAL
3. Inspect:
Specific gravity
Out of specification
Charge.
4. Install:
Filler caps
CAUTION:
Before installation, rinse off any fluid from
the battery box and battery and make sure
that the battery is dry before installing it.
Specific gravity at 20 °C (68 °F):
1.28
Charging current:
1.9 amps
×
10 hrs
5. Install:
Battery breather hose
1
Battery
Battery positive lead
2
Battery negative lead
3
Bands
CAUTION:
Connect the positive lead to the battery
terminal first.
Make sure the battery leads are con-
nected properly. Reversing the leads can
seriously damage the electrical system.
Make sure that the battery breather hose is
properly connected and is not obstructed.
Coat the terminals with a water resistant
grease to minimize terminal corrosion.
2
1
3