Service manual

ELECTRICAL COMPONENTS
8-100
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester (DC 20 V) to the
intake air pressure sensor coupler (wire
harness side) as shown.
b. Set the main switch to “ON”.
c. Measure the intake air pressure sensor
output voltage.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
EAS28420
CHECKING THE INTAKE AIR TEMPERA-
TURE SENSOR
1. Remove:
Intake air temperature sensor
(from the air filter case.)
WARNING
EWA14110
Handle the intake air temperature sensor
with special care.
Never subject the intake air temperature
sensor to strong shocks. If the intake air
temperature sensor is dropped, replace it.
2. Check:
Intake air temperature sensor resistance
Out of specification Replace.
▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼▼
a. Connect the pocket tester ( × 100) to the
intake air temperature sensor terminal as
shown.
b. Measure the intake air temperature sensor
resistance.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
3. Install:
Intake air temperature sensor
Intake air pressure sensor out-
put voltage
3.75–4.25 V
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe
Pink/White “1”
Negative tester probe
Black/Blue “2”
Intake air temperature sensor
resistance
2.21–2.69 k at 20°C (68°F)
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
Positive tester probe
Brown/White “1”
Negative tester probe
Black/Blue “2
Intake air temperature sensor
bolt
1.2 Nm (0.12 m·kg, 0.87 ft·lb)