MIDI Parameter Change Table
D12
MIDI Data Format
MIDI Parameter Change Table (MULTI EQ)
[ MIDI (Silent) ] [ Internal Sequencer ]
Address
(H)
Size
(H)
Data
(H)
Parameter Description
MIDI Reception MIDI Transmission Song Playback MIDI Recording
Song
Part
Piano
Playback
Channel
Panel
Operation
Song
Playback
MIDI
Input
PLAY
PLAY
(Piano
Part)
REW Piano Others
02 40 00 1 00-04 EQ TYPE flat, jazz, pops, rock, classic
× × × × × × × × × ×
01 1 34-4C EQ GAIN1 -12…0…+12 [dB]
× × × × × × × × × ×
02 1 04-28 EQ FREQUENCY1 32…2.0k [Hz]
× × × × × × × × × ×
03 1 01-78 EQ Q1 0.1…12.0
× × × × × × × × × ×
04 1 00-01 EQ SHAPE1 shelving, peaking
× × × × × × × × × ×
05 1 34-4C EQ GAIN2 -12…0…+12 [dB]
× × × × × × × × × ×
06 1 0E-36 EQ FREQUENCY2 100…10.0k [Hz]
× × × × × × × × × ×
07 1 01-78 EQ Q2 0.1…12.0
× × × × × × × × × ×
08 1 NOT USED
09 1 34-4C EQ GAIN3 -12…0…+12 [dB]
× × × × × × × × × ×
0A 1 0E-36 EQ FREQUENCY3 100…10.0k [Hz]
× × × × × × × × × ×
0B 1 01-78 EQ Q3 0.1…12.0
× × × × × × × × × ×
0C 1 NOT USED
0D 1 34-4C EQ GAIN4 -12…0…+12 [dB]
× × × × × × × × × ×
0E 1 0E-36 EQ FREQUENCY4 100…10.0k [Hz]
× × × × × × × × × ×
0F 1 01-78 EQ Q4 0.1…12.0
× × × × × × × × × ×
10 1 NOT USED
11 1 34-4C EQ GAIN5 -12…0…+12 [dB]
× × × × × × × × × ×
12 1 1C-3A EQ FREQUENCY5 0.5k…16.0k [Hz]
× × × × × × × × × ×
13 1 01-78 EQ Q5 0.1…12.0
× × × × × × × × × ×
14 1 00-01 EQ SHAPE5 shelving, peaking
× × × × × × × × × ×
TOTAL SIZE 15
* The MULTI EQ parameter cannot be reset to its factory setting with XG SYSTEM on.
MIDI Parameter Change Table (EFFECT2)
[ MIDI (Silent) ] [ Internal Sequencer ]
Address
(H)
Size
(H)
Data
(H)
Parameter Description
MIDI Reception MIDI Transmission Song Playback MIDI Recording
Song
Part
Piano
Playback
Channel
Panel
Operation
Song
Playback
MIDI
Input
PLAY
PLAY
(Piano
Part)
REW Piano Others
03 n 00 2 00-7F INSERTION EFFECT TYPE MSB Refer to Effect Parameter List
× × × × × × × × ×
00-7F INSERTION EFFECT TYPE LSB
02 1 00-7F INSERTION EFFECT PARAMETER 1 Refer to Effect Parameter List
× × × × × × × × ×
03 1 00-7F INSERTION EFFECT PARAMETER 2 Refer to Effect Parameter List
× × × × × × × × ×
04 1 00-7F INSERTION EFFECT PARAMETER 3 Refer to Effect Parameter List
× × × × × × × × ×
05 1 00-7F INSERTION EFFECT PARAMETER 4 Refer to Effect Parameter List
× × × × × × × × ×
06 1 00-7F INSERTION EFFECT PARAMETER 5 Refer to Effect Parameter List
× × × × × × × × ×
07 1 00-7F INSERTION EFFECT PARAMETER 6 Refer to Effect Parameter List
× × × × × × × × ×
08 1 00-7F INSERTION EFFECT PARAMETER 7 Refer to Effect Parameter List
× × × × × × × × ×
09 1 00-7F INSERTION EFFECT PARAMETER 8 Refer to Effect Parameter List
× × × × × × × × ×
0A 1 00-7F INSERTION EFFECT PARAMETER 9 Refer to Effect Parameter List
× × × × × × × × ×
0B 1 00-7F INSERTION EFFECT PARAMETER 10 Refer to Effect Parameter List
× × × × × × × × ×
0C 1 00-7F INSERTION EFFECT PART NUMBER Reception: Part1…16 (0…15)
× × × × × × × × ×
Transmission: Part1…16
(0…15)
AD (64)
OFF (127)
0D 1 00-7F MW INSERTION CONTROL DEPTH -64…0…+63
× × × × × × × × ×
0E 1 00-7F BEND INSERTION CONTROL DEPTH -64…0…+63
× × × × × × × × ×
0F 1 00-7F CAT INSERTION CONTROL DEPTH -64…0…+63
× × × × × × × × ×
10 1 00-7F AC1 INSERTION CONTROL DEPTH -64…0…+63
× × × × × × × × ×
11 1 00-7F AC2 INSERTION CONTROL DEPTH -64…0…+63
× × × × × × × × ×
TOTAL SIZE 12
20 1 00-7F INSERTION EFFECT PARAMETER 11 Refer to Effect Parameter List
× × × × × × × × ×
21 1 00-7F INSERTION EFFECT PARAMETER 12 Refer to Effect Parameter List
× × × × × × × × ×
22 1 00-7F INSERTION EFFECT PARAMETER 13 Refer to Effect Parameter List
× × × × × × × × ×
23 1 00-7F INSERTION EFFECT PARAMETER 14 Refer to Effect Parameter List
× × × × × × × × ×
24 1 00-7F INSERTION EFFECT PARAMETER 15 Refer to Effect Parameter List
× × × × × × × × ×
25 1 00-7F INSERTION EFFECT PARAMETER 16 Refer to Effect Parameter List
× × × × × × × × ×
TOTAL SIZE 6
30 2 00-7F
INSERTION EFFECT PARAMETER 1 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 1 LSB
32 2 00-7F
INSERTION EFFECT PARAMETER 2 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 2 LSB
34 2 00-7F
INSERTION EFFECT PARAMETER 3 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 3 LSB
36 2 00-7F
INSERTION EFFECT PARAMETER 4 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 4 LSB
38 2 00-7F
INSERTION EFFECT PARAMETER 5 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 5 LSB
3A 2 00-7F
INSERTION EFFECT PARAMETER 6 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 6 LSB
3C 2 00-7F
INSERTION EFFECT PARAMETER 7 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 7 LSB
3E 2 00-7F
INSERTION EFFECT PARAMETER 8 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 8 LSB
40 2 00-7F
INSERTION EFFECT PARAMETER 9 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 9 LSB
42 2 00-7F
INSERTION EFFECT PARAMETER 10 MSB
Refer to Effect Parameter List
× × × × × × × × ×
00-7F
INSERTION EFFECT PARAMETER 10 LSB
TOTAL SIZE 14
* The EFFECT2 parameter cannot be reset to its factory setting with XG SYSTEM on.
The second byte of the address is considered as an insertion effect number.
n: insertion effect number
The insertion effect number range is from 0 to 1. Values outside the range are handled as unknown and ignored.
For effect types that do not require MSB, the parameters for address 02-0B will be received and the parameters for address 30-42 will not be received.
For effect types that require MSB, the parameters for address 30-42 will be received and the parameters for address 02-0B will not be received.
When bulk dumps that include effect type data are transmitted, the parameters for address 02-0B will always be transmitted. However, for effect types that require MSB, the parameters for
address 02-0B will not be received when the bulk dump is received.