Service manual

7-13
E
–+
ELEC
IGNITION SYSTEM
2. Measure:
Secondary coil resistance
Out of specification Replace.
Secondary coil resistance:
Spark plug cap – Spark plug cap
14.3–30.5 k at 20 ˚C (68 ˚F)
ENGINE STOP SWITCH
1. Check:
Engine stop switch continuity
Out of specification Replace.
Engine stop switch continuity
(black coupler)
Lock plate Position
Lead color
White Black
Installed
Free
Push
Removed
Free
Push
THERMOSWITCH
1. Measure:
Thermoswitch continuity
Out of specification Replace.
1 No continuity Å Temperature
2 Continuity ı Time
Thermoswitch continuity
temperature:
Pink (P) – Black (B)
a 80 ˚C (177 ˚F)
b 70 ˚C (159 ˚F)
Measurement steps:
Suspend the thermostat in a container
filled with water.
Place a thermometer in the water.
Slowly heat the water.
Measure the continuity when the spec-
ified temperature is reached.