Service manual

3-5
INSP
ADJ
E
CONTROL SYSTEM
QSTS cable inspection and adjustment
1. Measure:
Nozzle deflector set length a, b
Difference Adjust.
Measurement steps:
Set the control grip in the neutral posi-
tion.
Measure the nozzle deflector set
length a and b.
If a and b length are not even, adjust
the cable joint.
2. Adjust:
QSTS cable
Adjustment steps:
Set the control grip in the neutral posi-
tion.
Loosen the locknut 1.
Remove the nut 2 and pivot pin 3.
Set the nozzle deflector in the center
position.
Turn the cable joint 4 for adjusting.
Turn in Length b is increased.
Turn out Length a is increased.
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
Connect the cable joint 4 and pivot
pin 3 and tighten the nut 2.
T
R
.
.
Nut:
4 N • m (0.4 kgf • m, 2.9 ft • lb)
Tighten the locknut 1.
T
R
.
.
Locknut:
4 N • m (0.4 kgf • m, 2.9 ft • lb)