User Manual
Table Of Contents
- Notice regarding data copyright
- Notice regarding the content of this user guide
- Contents
- Chapter 1. An overview of MTX-MRX Editor
- An audio system control network
- Terms used in this user guide
- Data handled by MTX-MRX Editor
- Connection requirements for an MTX/MRX system
- MTX/MRX system configuration examples
- What are YDIF connections? (Cascade mode and Distribution mode)
- What are Dante connections? (Daisy-chain connection and Star connection)
- Patching
- Workflow
- About the screens
- Moving between screens
- Chapter 2. Menu bar and tool buttons
- Chapter 3. Project screen
- Chapter 4. System screen
- Chapter 5. Online and Synchronization
- Chapter 6. Presets
- Chapter 7. Dialog boxes/Software applications
- “Startup” dialog box
- “Network Setup” dialog box
- “Device Information” dialog box
- “Match Device by IP Address” dialog box
- “MTX Configuration” dialog box
- “Dante Information” dialog box
- “Word Clock” dialog box
- “Clock” dialog box
- “Daylight Saving Time” dialog box
- “Scheduler” dialog box
- “Remote Control” dialog box
- “External Events” dialog box
- “Digital Control Panel” dialog box
- “Wireless DCP” dialog box
- “MCP1” dialog box
- “PIN Setup” dialog box
- “Label” dialog box
- “Re-size Image” dialog box
- “PGM1/PGX1” dialog box
- “PGM1 Label Creator” application
- “GPI” dialog box
- “GPI Calibration” dialog box
- “Security Settings” dialog box
- “Project Information” dialog box
- “Configuration Diagram” dialog box
- “Get Log” dialog box
- “Sampling Rate Converter” dialog box
- “Input Source/Redundant” dialog box
- Appendix
List of settings in “Settings” dialog boxes Appendix
MTX-MRX Editor User Guide
259
About [OUTPUT TYPE]
[OUTPUT TYPE] allows the following settings.
• Closed
• Open
• Pulse
• Pulse Inv.
❍ Closed
When the selected [FUNCTION] state occurs, the contact will be closed.
In the case of a parameter for which [Threshold] is specified, the contact will be
closed when the threshold value is exceeded.
❍ Open
When the selected [FUNCTION] state occurs, the contact will be opened.
In the case of a parameter for which [Threshold] is specified, the contact will be
opened when the threshold value is exceeded.
If the [FUNCTION] is [Alert], this cannot be selected.
❍ Pulse
If the [Direction] is [Upward], the contact will change from open to closed for
approximately 250 ms when the selected [FUNCTION] state occurs. In the case of a
parameter for which [Threshold] is specified, the contact will change from open to
closed for approximately 250 ms when the threshold value is exceeded.
If the [Direction] is [Downward], the contact will change from open to closed for
approximately 250 ms when the selected [FUNCTION] state is cleared. In the case
of a parameter for which [Threshold] is specified, the contact will change from open
to closed for approximately 250 ms when the value falls below the threshold.
If the [FUNCTION] is [SD Song Play] and [Alert], this cannot be selected.
❍ Pulse Inv.
If the [Direction] is [Upward], the contact will change from closed to open for
approximately 250 ms when the selected [FUNCTION] state occurs. In the case of a
parameter for which [Threshold] is specified, the contact will change from closed to
open for approximately 250 ms when the threshold value is exceeded.
If the [Direction] is [Downward], the contact will change from closed to open for
approximately 250 ms when the selected [FUNCTION] state is cleared. In the case
of a parameter for which [Threshold] is specified, the contact will change from
closed to open for approximately 250 ms when the value falls below the threshold.
If the [FUNCTION] is [SD Song Play] and [Alert], this cannot be selected.
● If [FUNCTION] is [No Assign]
[OUTPUT TYPE] specifies the polarity of the output signal when an alert occurs. No
other function are specified; they will be the default.
❍ [OUTPUT TYPE]
Controls the GPI OUT when a preset is recalled or when a Scheduler event is
executed.
NOTE
NOTE
NOTE