MTX3/MTX5-D/MRX7-D/XMV Series/EXi8/EXo8 Remote Control Protocol Specications V3.1.0 rev10
16
3. Command Specications
3.2.3. Meter information notication
1-7) Meter information notication
MTX3,MTX5-D,XMV,EXi8,EXo8
Command Option 1 Option 2 Option 3 Description
NOTIFY mtr MTX:mtr_MemNo/UniqueId/meter level (meter) Level meter value
gr gr meter value
Details: MemNo = See section 8, "Meters."
UniqueId = See section 8, "Meters."
(meter) = See section 5, "Meter Values."
Example: Notication: NOTIFY mtr MTX:mtr_512/20020/meter level 71 71 71 71 71 71 69 68
* The meter value is expressed using a 2-digit hexadecimal.
Meaning: Output levels for ch1 to 8 Level are sent.
MRX7-D
Command Option 1 Option 2 Option 3 Description
NOTIFY mtr MTX:Index_IndexNo level (meter) Level meter value
gr gr meter value
hold Hold meter value
Details: IndexNo = Index number assigned in Remote Control Setup List
(meter) = See section 5, "Meter Values."
Example: Notication: NOTIFY mtr MTX:Index_2 level 71 71 71 71 71 71 69 68
(V2.02 or earlier NOTIFY mtr MTX:Index_002 level 71 71 71 71 71 71 69 68)
* The meter value is expressed using a 2-digit hexadecimal.
Meaning: Output levels for Ch1 to 8 which are assigned to Index 2 in Remote Control list are sent.
3.2.4. Preset change notication
1-8) Current Preset number change notication
Command Option 1 Description
NOTIFY sscurrent (index) Current preset number change notication
Details: (index) = Current preset index number
Example: Notication: NOTIFY sscurrent 10
Meaning: Current preset was changed to index 10 (preset 10).
1-9) Preset recall start notication
Command Option 1 Description
NOTIFY ssrecall (index) Preset recall process started
Details: (index) = Preset index number
Example: Notication: NOTIFY ssrecall 10
Meaning: Preset recall process for Index 10 preset started.