13PGM1/PGX1 Installation Manual
Initializing the PGM1
If you want to return (initialize) the unit to its factory-set state, for example because the installa-
tion location has changed, proceed as follows.
1. Power-off the PSE.
2. On the rear panel, set device settings
DIP switch 7 to the downward posi-
tion, and set switch 8 to the upward
(INT.) position.
3. Power-on the PSE.
Initialization begins.
Initialization in progress:
All zone indicators flash rapidly.
Initialization completed:
All zone indicators flash slowly.
Initialization failed:
The status indicator flashes slowly.
4. Verify that initialization is completed,
and then power-off the PSE.
5. Set device settings DIP switches 7
and 8 both to the upward (RESUME)
position.
6. Power-on the PSE.
The unit starts up in the factory-set
state.
NOTICE
Do not power-off the PSE while initializa-
tion is in progress. Doing so will cause
malfunctions.