User Manual

Table Of Contents
Dante Controller User Guide
Copyright © 2014 Audinate Pty Ltd. All rights reserved.
-38-
Where the checkbox is present but greyed-out (and inactive), it means that the Dante device
can
be slaved
to an external word clock, but it cannot be set directly from Dante Controller - it must be done via the host
device user interface, or via some other method (e.g. third-party control software). If the checkbox is
greyed out and populated, it means that the Dante device is currently slaved to the external clock.
If N/A is displayed, it means that the device does not support slaving to an external word clock.
Note: If no clock status information is displayed for a particular device, it can indicate a ConMon
(Dante control and monitoring service) failure on the device. The device may need to be reset or
restored.
About Clock Domains
Dante Devices that are
not
configured with sample rate pull-up/down operate on the default clock domain,
using the default clock. Devices that
are
configured with sample rate pull-up/down operate on separate
'clock domains', which have their own dedicated PTP clocks, adjusted to account for the pulled up/down
sample rates.
Clock domains are not physically separated, they all exist on the network simultaneously. Devices with
pull-up/down synchronise to the appropriate clock for their pull-up/down setting, and ignore other clocks.
Those devices are shown with the relevant pull-up/down value against their Clock Status in the Clock
Status tab.
Dante devices can only transmit audio to, and receive audio from other devices on the same clock domain.
For example, a device with zero sample rate pull-up/down operates on the default clock domain, and
cannot transmit audio to, or receive audio from any devices on the +4.1667% clock domain, or the -1%
clock domain, etc.
Up to 5 separate clock domains can be supported at any one time. All clock domains have their own
master clock.
About Master Clocks
The Dante network master clock (often also referred to as the 'Grand Master'), is displayed at all times in
the center of the toolbar of the Network View. This is the device that is providing the time sync source for
all devices on the network.
If multiple clock domains are in use, the master clock for each domain is shown, in a comma-separated
list.
The master clock is chosen automatically through an election process, though there are user configurable
parameters that allow prioritization of some devices in the master clock election. Configuring a device to
have an external word clock source will force that device to become master clock, unless another device
has 'Preferred Master' set.
Checking the 'Preferred Master' flag will always result in that device (or the device with the lowest MAC
address, if more than one device has been checked) becoming master clock for that domain.
Note: If the master clock device is not directly visible to Dante Controller (for example, if the master
clock device is for some reason only connected to the secondary network, and Dante Controller is
only connected to the primary network), the 'Master Clock' display in the toolbar may show a
MACaddress string, instead of the device name.