User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Centralogic section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon and channel color
- Making HA (Head Amp) settings
- Sending a signal from an input channel to the STEREO/MONO buses
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Correcting delay between channels (Input Delay)
- Channel library operations
- Output channels
- EQ and Dynamics
- Grouping and linking
- Scene memory
- About scene memories
- Using scene memories
- Editing scene memories
- Using the Global Paste function
- Using the Focus function
- Using the Recall Safe function
- Using the Fade function
- Outputting a control signal to an external device in tandem with scene recall (GPI OUT)
- Playing back an audio file that links to a scene recall
- Using Preview mode
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, effects, and Premium Rack
- I/O device and external head amp
- MIDI
- User settings (Security)
- Recorder
- Help function
- Other functions
- About the SETUP screen
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the channel color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Dante audio network settings
- Using GPI (General Purpose Interface)
- Appendices
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Effects and tempo synchronization
- Parameters that can be assigned to control changes
- NRPN parameter assignments
- Mixing parameter operation applicability
- Functions that can be assigned to USER DEFINED keys
- Functions that can be assigned to USER DEFINED knobs
- Functions that can be assigned to the assignable encoders
- MIDI Data Format
- Warning/Error Messages
- Electrical characteristics
- Mixer Basic Parameters
- M IDI Implementation Chart
- Index
I/O device and external head amp
Reference Manual
144
Using an external head amp
If an I/O card (such as an MY16-ES64 card) supports the remote protocol of an external head amp in
the CL’s slot, you will be able to remotely control from the CL console some parameters of the external
head amp (Yamaha SB168-ES or AD8HR), such as phantom power (+48V) on/off status, gain, and HPF.
For details on the I/O card settings, refer to the owner’s manual for the I/O card.
Connecting the CL series console to an AD8HR
To remotely control the AD8HR from the CL series console, install an MY16-ES64 EtherSound card in
Slot 1 on the CL unit, then use an Ethernet cable to connect the CL unit to the NAI48-ES. Then, connect
the HA REMOTE connector on the NAI48-ES to the HA REMOTE 1 connector on the AD8HR using
an RS422 D-sub 9-pin cable. This connection enables you to remotely control the AD8HR from the CL
series console.
To transmit audio signals (input to the AD8HR) to the CL series console, connect the DIGITAL OUT
A (or B) connector on the AD8HR to the AES/EBU connector on the NAI48-ES using a D-sub 25-pin
AES/EBU cable. Signals will be sent or received between the NAI48-ES and the CL series console via
the MY16-ES64 card.
Alternatively, you can use a “daisy chain” connection to remotely control multiple AD8HR units
simultaneously. To do this, connect the AD8HR’s HA REMOTE 2 connector to the second AD8HR’s
HA REMOTE 1 connector. If you use the NAI48-ES, you can connect up to six AD8HR units. In this
case, to input AD8HR’s audio signals into the CL series console, install two MY16-EX cards on the CL
unit since each slot on the CL unit accepts up to 16 channel signals. Then, use an Ethernet cable to make
connections to the MY16-ES64.
CL5
AD8HR 1
NAI48-ES
AD8HR 2
AD8HR 3
MY16-
EX
MY16-
EX
MY16-
ES64
DIGITAL OUT A connector
DIGITAL OUT A
connector
DIGITAL
OUT A
connector
HA REMOTE connector
HA REMOTE 1 connector
HA REMOTE 2 connector
Up to six units
Audio signal
Remote signal
HA REMOTE 2 connector
HA REMOTE 2 connector
HA REMOTE 1 connector
HA REMOTE 1 connector